This gas fireplace vent goes through a closet filled with combustible clothes. Obviously, no consideration was given to fire safety or the welfare of the homes occupants. It is supposed to be contained inside a properly spaced enclosure. This installation needs to be correctly and safely completed by a qualified specialist, immediately.

 

Back to Top...



This is a picture of a closet wall extensively damaged by mould. The humidifier on the furnace in this house was set at 60% plus. (Way too high. We recommend 25% max., winter only)  This damaged wall in this closet is also an exterior wall of this house. As a result, it is colder than the other walls in the closet. Add to that, the fact that this closet also contains the uninsulated access hatch to the attic, and you have a recipe for significant condensation and the resulting mould and damage.

 

Back to Top...



This third floor window at these stairs needs a railing to protect against someone falling through the window three floors to the concrete walkway between these homes. The window is a standard thermal window. It is not a plate glass window. The railing should be installed in front of this window immediately, for safety and legal liability sake.

 

Back to Top...



This brand new home was supposed to have Nine and a half inches of insulation. It only had five and a half inches.  Another good reason to have your NEW home inspected.

 

Back to Top...



This basement renovation in progress was being done without a vapour barrier. All the drywall had to come off so the vapour barrier could be applied - To avoid moisture/mould/mildew developing in the walls.

 

Back to Top...

 